The following table lists the changes that have been made to the
CVE-2025-11784 vulnerability over time.
Vulnerability history details can be useful for understanding the evolution
of a vulnerability, and for identifying the most recent changes that may
impact the vulnerability’s severity, exploitability, or other characteristics.
-
New CVE Received
by [email protected]Dec. 02, 2025
Action Type Old Value New Value Added Tag unsupported-when-assigned Added Description Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the ‘ShowMeterDatabase()’ function, there is an unlimited user input that is copied to a fixed-size buffer via ‘sprintf()’. The ‘GetParameter(meter)’ function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the ‘meter’ parameter. Added CVSS V4.0 AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Added CWE CWE-121 Added Reference https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0